SC150mm – SC300mm Profile – Double Side Application – Wall Panel above Surecove
Installation Procedure
Double Side Application – Wall Panel above Surecove
- Saw- cut 6 mm width x 15 mm depth, adjacent to the wall, off set 305 mm apart, outide line to outside line of saw-cut, for 100 mm thick wall panel
- Clean / remove dust and debris from wall and saw-cut, ensure surfaces are dry
- Drill holes and place N12 starter bars @ 400 mm centres, between saw-cuts
- Drill 8 mm holes in floor for brackets, offset 110 mm from outside line of saw-cut at 800 mm centres
- Place Steel retaining brackets with 60 mm masonary sleeve anchors
- Cut Surecove product length to suit application
- Apply 2 – Part Epoxy (Sikadur 31) x 60mm, into Saw-cut at 600mm centres and at corner sections with Spatula
- Place Surecove into saw-cut, joining lengths with Surecove offcuts to rear face with Loctite 406 adhesive
- Using a string line, align Surecove product at top, and tighten masonary sleeve anchors to secure brackets
- Apply Sikaflex 11fc along saw-cut and bottom of Surecove product to seal, after epoxy has hardened / cured
- Place and tie N12 rod longitudinally to N12 starter bars and backfill Surecove product with concrete mix